4

ora-04091 表XX发生了变化 触发器/函数不能读 的错误处理

by 刘武 11. 五月 2009 21:26

开发过程中碰到了ora-04091错误:表XX发生了错误,触发器/函数不能读

以下是模拟场景:

表PRODUCTS:

CREATE TABLE CKSP.PRODUCTS
(
    ID     NUMBER(1)     NOT NULL,
    NAME   VARCHAR2(100) NOT NULL,
    PRICE1 NUMBER(1)     NOT NULL,
    PRICE2 NUMBER(1)     NOT NULL
)
TABLESPACE USERS
NOLOGGING
PCTFREE 10
PCTUSED 0
INITRANS 1
MAXTRANS 255
STORAGE(BUFFER_POOL DEFAULT)
NOPARALLEL
NOCACHE

 

并声明触发器TRG_PRODUCTS_INSERT:

CREATE OR REPLACE TRIGGER TRG_PRODUCTS_INSERT
BEFORE INSERT
ON PRODUCTS
REFERENCING OLD AS OLD NEW AS NEW
FOR EACH ROW
declare 
varCount number;
begin  
	select count(id) into varCount from products where name = :new.name;
	if varCount > 0 then
		varCount:= varCount +1;
		:new.name :=varCount||'_'||:new.name;
	end if;
    
end;

 

若执行以下SQL则会引发ORA-04091错误

begin
    insert into products values(1,'p1',1,2);
    insert into products 
    select 2 as id ,name ,price1,price2 from products where id= 1;
end;

 

解决方法:修改SQL 如下

declare
    varName varchar2(100);
    varPrice1 number;
    varPrice2 number;
begin
    insert into products values(1,'p1',1,2);
    select name,price1,price2 into varName,varPrice1,varPrice2 from products where id =1;
    insert into products values(2,varName,varprice1,varPrice2);    
end;

 

在此情形中不能使用INSERT INTO XXX SELECT .... 语句,而应使用变量来保存值

这也许只是众多情形之一,仅供参考.